Flir ELARA FR-345-EST FLIR Elara™ FR-345-EST™ Part # 427-0108-00-

Flir ELARA FR-345-EST FLIR Elara™ FR-345-EST™ Part # 427-0108-00-
$5,409.00
Out of stock
Product Description
ELARA FR-345-EST:FLIR Elara™ FR-345-EST™ Part # 427-0108-00-00
The FLIR Elara FR-345-EST is an affordable, fixed-mount radiometric camera for accurately measuring skin temperature at medium- to high-throughput entry control points. Equipped with on-edge, intelligent face detection, Elara FR-345-EST issues on-screen prompts to individuals when they need to remove glasses, while also guiding them to the correct position for best measurement. The non-contact camera automatically locates and measures the inner canthus (corner of the eye) within one second and provides an instant pass/fail graphic to the individual. Integration with VMS systems further streamlines workflow and decision-making for facilities, while helping security personnel maintain a safe distance from potential health risks. Elara FR-345-EST does not require or save personally identifiable information (PII) for skin temperature screening.
General
- Detector Type
- Long-Life, Uncooled VOx Microbolometer
- Input Voltage
- 12-30 VDC (±10%), 24 VAC (21-28 VAC), 802.3at (PoE+)
- Model
- 345
- Power Consumption
- 17 W
- Visible Sensor Type
- 1920 x 1080
Cyber Security
- Security
- IEEE 802.1x, TLS Authentication – control & streaming, Digest authentication, HTTPS encryption, Encrypted FW upload, Access control via firewall
Environmental
- Humidity
- 0-95% relative
- IP Rating (dust & water ingress)
- IP54
- Operating Temperature Range
- 15 to 45°C
- Storage Temperature Range
- -40 to 70°C
- Vandal Resistance
- IK10
Measurement & Analysis
- Accuracy [Drift] in Screening Mode
- ±0.5°C (±0.9°F)
- Object Temperature Range
- 15 to 45°C (59 to 113°F); camera provides contrast from -20 to 120°C (-4 to 248°F) but will not provide temperature information
- Screening Mode Subject Distance
- 1m ± 0.2m
System Integration
- Digital I_O
- Input: one dry alarm contact
Output: one photo relay contact 1A max at 24 VAC/30 VDC
- Ethernet
- 10/100 Mbps
- Network APIs
- FLIR SDK
FLIR CGI
ONVIF Profile S
- Streaming Resolution
- Thermal: upscaled to VGA (640 × 480)
Visible: 1080p (1920 × 1080), 720p (1280 × 720), VGA (640 × 480)
Thermal Camera
- Array Format (NTSC)
- 320 x 256
- Pixel Pitch
- 17 µm
- Thermal f number
- 1.5
- Thermal Frame Rate
- 20Hz
Video & Recording
- Video Compression
- Two independent channels of H.264 or M-JPEG for visible
One channel of H.264 or M-JPEG for thermal
Visible Camera
- Field of view (FOV)
- 45° × 34°
- Focal Length
- 4 mm
- Lens Field of View
- HFOV = 75°
VFOV = 44°
- Sensitivity
- 0.05 Lux (at f1.6 AGC ON, 30FPS)
- Visible f number
- 1.6
Additional Information
Weight | 10 lbs |
---|---|
Dimensions | 10 × 10 × 10 in |
Reviews
There are no reviews yet.
Be the first to review “Flir ELARA FR-345-EST FLIR Elara™ FR-345-EST™ Part # 427-0108-00-”